6/4/2018
Posted by 
Medisense Precision Qid User Manual Download Free Software

Meters Glucometer Elite XL • Elite XL model has a button for manual on/off and to go back through stored readings • stores 120 readings in memory, with date and time taken • has a data port to download stored readings to a computer via an optional cable • can delete a reading if strip has not yet been removed • can designate a reading as a control before or after getting it • How the Bayer Elite model Differs from the Elite XL Bayer has Customer Service Representatives available 24 hrs a day, 7 days a week to assist you with using your meter. (800) 348-8100 Glucometer Elite • Elite does NOT have a button • only stores 20 readings in memory • does not display or store time and date • does not have data port to download stored readings to a computer via an optional cable • to View readings stored in memory, you need either a Check Strip or a new Test Strip Insert Check Strip (says CHECK) and wait 10 sec. For memory to activate. How To Decode Php Files That Encoded By Zend Encoderpro. OR insert a new Test Strip and wait 3 min.

For memory to activate. Average of the stored Test Results will display first, then 1 and the most recent result, 2 and the next most recent result through 20 and the oldest result. END displays when you have viewed all readings. • to Delete the last test result: before the meter shuts off, pull out the used Test Strip and re-insert it within 2 sec • to Mark a test as a Control: insert a new Test Strip, pull out the new Test Strip and re-insert it within 2 sec, a C will display. Touch test end of the strip to the drop of Control Solution. How the Bayer Dex model differs from the Elite XL Glucometer Dex (Esprit outside U.S. Trench Warfare Game Mission 40 on this page. ) • The Dex is somewhat harder to use than the Elites in that the angle that the strip is held to the drop is less flexible.

Test both blood glucose and blood ketone all with the Precision Xtra system. Includes intuitive setup and simple icon-driven menus. Data Management Software.

For accurate results, meter should be held horizontal and blood sample should be sipped for 1-2 sec. After the beep and count-down start, no longer. An insufficient fill will give a falsely lower or Lo reading, an overfill can give a higher than actual reading. The sensor has an open end and an overfill can draw blood into the meter electronics and short them out.

Once dry, the meter should work okay again, but do a Control test to verify it. Visual inspection of the Dex sensor to determine if it filled enough is not as reliable as with the Elite strips. • The Dex uses a cartridge of 10 test sensors instead of individual strips, sometimes a sensor doesn't pop out properly and can't be used. After use, sensors are ejected without being handled. Exercise Corrigo Java Pdf Generator here. • automatically calibrates the test sensor cartridge, no Code strip needed • has 2 buttons at the bottom, A on the left and & B on the right of the meter • displays overall average and four 2-hr time-range averages • uses a different version of the Win Glucofacts software (it is meter-specific) • The Glucometer Elite XL, Elite, and the DEX are referenced to give plasma/serum glucose values when testing capillary whole blood and will compare directly to your laboratory results.

A meter referenced to whole blood will give results 10% - 15% lower than the Glucometer DEX and your laboratory results. • the sensor strips are very short and some have had problems with blood getting into the meter where it is not meant to go when their pet moved. LifeScan ONE TOUCH FastTake with new FastDraw strips LifeScan will no longer make the FastTake Blood Glucose meter effective November 10,2001.

Consider the LifeScan Ultra model, which has received excellent reviews. (FastTake was also marketed under the brand names: SmartScan®, EuroFlash® and PocketScan®) Differences from the Elite XL • FastDraw strips 'sip up' (new 6/00), older versions did not • Smaller sample 1,5 ul, not 3.0 • Only 15 sec.

To see result, not 30 • Automatic shut-off after 2 min, not 3 • Stores 150 tests, not 120 • Doesn't beep • If reading is 240 or higher, it displays ketones? As a reminder to test for ketones (do a urine test with Ketostix). It does not mean ketones were detected, these strips do not measure ketones.• Meter won't start to count down until the white target area is filled, but if the sample is still not sufficient, the FastTake meter will give a false low reading (20s-30s) or an Er message. The new strip with the confirmation window helps you know if you have a sufficient sample, but if the meter is already counting down, it's too late to add blood. The confirmation window must be completely filled to get a valid reading. Use a new strip and repeat the test when you get an Er message or a suspiciously low reading.